|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
50W Single Output Switching Power Supply Features : Universal AC input / Full range LPS-50 series Protections:Short circuit/Over load/Over voltage Cooling by free air convection Small and compact size Built-in remote ON-OFF control LED indicator for power on 100% full load burn-in test Low profile:23mm thickness 2 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD(10sec.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY(Typ.) INPUT AC CURRENT (Typ.) 115VAC 230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE FUNCTION REMOTE ON/OFF WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 5) LPS-50-3.3 3.3V 10A 0 ~ 12A 33W Note.4 39.6W LPS-50-5 5V 10A 0 ~ 12A 50W 60W 50mVp-p 4.5 ~ 5.5V 3.0% 1.0% 3.0% LPS-50-12 12V 4.2A 0 ~ 5A 50.4W 60W 80mVp-p 10.8 ~ 13.2V 2.0% 1.0% 2.0% LPS-50-15 15V 3.4A 0 ~ 4.1A 51W 61.5W 80mVp-p 13.5 ~ 16.5V 2.0% 1.0% 2.0% LPS-50-24 24V 2.1A 0 ~ 2.5A 50.4W 60W 80mVp-p 21.6 ~ 27.2V 1.0% 1.0% 1.0% LPS-50-48 48V 1.1A 0 ~ 1.3A 52.8W 62.4W 100mVp-p 43.2 ~ 52.8V 1.0% 1.0% 1.0% RIPPLE & NOISE (max.) Note.2 50mVp-p 3 ~ 3.6V 3.0% 1.0% 3.0% 100ms, 40ms/230VAC 70ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 75% 0.9A 0.6A 100ms, 40ms/115VAC at full load 12ms/115VAC at full load 127 ~ 370VDC 81% 1.2A 0.8A 35A/230VAC 82% 84% 85% 86% COLD START 18A/115VAC <1mA / 240VAC 122 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Hiccup mode, recovers automatically after fault condition is removed RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 27.6 ~ 32.4V 57.6 ~ 67.2V I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 341.7Khrs min. MIL-HDBK-217F (25 195*55*23mm (L*W*H) 0.24Kg; 48pcs/12.5Kg/0.84CUFT ) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:LPS-50-SPEC 2006-04-13 50W Single Output Switching Power Supply Mechanical Specification 195 185 LPS-50 series Unit:mm CN1 5 4 3 2 1 1 CN3 2 1 2 CN2 3 4 55 45 SVR1 LED 4- 3.8 23 DC Output Connector (CN2) : JST B4P-VH or equivalent AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment AC/L No Pin AC/N FG Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 Assignment -V +V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent Pin No. 1 2 Assignment RC+ RCMating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent Block Diagram RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER fosc : 60KHz EMI FILTER +V -V I/P FG O.L.P. PWM CONTROL DETECTION CIRCUIT O.V.P. RC+ RC- Derating Curve Static Characteristics (15V) Ta=25 100 21 300 250 200 150 100 50 25 18 80 1 1 Convection 2 18CFM Forced Air 15 12 9 6 3 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) 60 90 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPS-50-SPEC 2006-04-13 OUTPUT RIPPLE (mVp-p) 2 OUTPUT VOLTAGE (V) LOAD (%) 100W Single Output without PFC Function Features : LPS-100 series Universal AC input / Full range Protections:Short circuit/Over load/Over voltage Cooling by free air convection 100% full load burn-in test Fix switching frequency at 134KHz 3 years warranty SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE LPS-100-3.3 LPS-100-5 3.3V 20A 0 ~ 20A 66W 5V 20A 0 ~ 20A 100W 100mVp-p 4.5 ~ 5.7V 3.0% 0.5% LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48 7.5V 13.3A 0 ~ 13.3A 99.75W 100mVp-p 6 ~ 9V 2.0% 0.5% 12V 8.4A 0 ~ 8.4A 100.8W 100mVp-p 10 ~ 13.2V 2.0% 0.5% 13.5V 7.5A 0 ~ 7.5A 101.25W 100mVp-p 12 ~ 15V 2.0% 0.5% 15V 6.7A 0 ~ 6.7A 100.5W 100mVp-p 13.5 ~ 18V 2.0% 0.5% 1.5% 24V 4.2A 27V 3.8A 48V 2.1A 0 ~ 2.1A 100.8W 200mVp-p 41 ~ 56V 1.0% 0.5% 0.5% 0 ~ 4.2A(6A 10s) 0 ~ 3.8A 100.8W(144W 10s) 102.6W 150mVp-p 20 ~ 26.4V 1.0% 0.5% 0.5% 150mVp-p 26 ~ 32V 1.0% 0.5% 0.5% RIPPLE & NOISE (max.) Note.2 150mVp-p 3 ~ 3.6V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC (Note 4) 0.5% 2.0% 2.0% 800ms, 50ms/230VAC 20ms/230VAC 47 ~ 63Hz 69% 2.3A/115VAC 77% 1.5% 1.5% 1.5% 1200ms, 50ms/115VAC at full load 248 ~ 370VDC 79% 79% 20ms/115VAC at full load 88 ~ 132VAC / 176 ~ 264VAC auto switch 77% 1.5A/230VAC 60A/230VAC 80% 80% 81% 81% COLD START 30A/115VAC <1mA / 240VAC 105 ~ 140% (+24V: above 6.5A) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 9.4 ~ 10.9V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 33.7 ~ 39.2V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 EMS IMMUNITY MTBF Compliance to EN61000-4-2,3,4,5,6,11, Light industry level, criteria A 203.6Khrs min. MIL-HDBK-217F (25 222*62*32mm (L*W*H) 0.45Kg; 24pcs/12.5Kg/1.76CUFT ) OTHERS NOTE DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24). 6. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:LPS-100-SPEC 2006-03-10 100W Single Output without PFC Function Mechanical Specification 222 5 212 LPS-100 series Unit:mm 5 FG CN2 CN1 1 2 3 4 5 8 7 6 5 4 3 2 1 62 52 AC FUSE F4A/250V +V ADJ. 43.5 AC Input Connector (CN1) : JST B5P-VH or equivalent Pin No. 1 2,4 3 5 Assignment FG No pin AC/N AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 32 DC Output Connector (CN2) : JST B8P-VH or equivalent Pin No. 1,2,3,4 5,6,7,8 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent Block Diagram 115/230VAC AUTO SWITCH RECTIFIERS & FILTER POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT O.V.P. fosc : 135KHz +V -V I/P EMI FILTER FG O.L.P. PWM CONTROL Output Derating Static Characteristics (12V) Ta=25 100 12 80 250 200 150 100 LPS-100-5V 60 11 10 9 +12V 8 7 LOAD (%) Convection (3.3V,7.5V~48V) 40 50 25 20 -10 0 10 20 30 40 50 60 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:LPS-100-SPEC 2006-03-10 OUTPUT RIPPLE (mVp-p) 18 CFM min Forced Air 13 +12V 300 OUTPUT VOLTAGE (V) |
Price & Availability of LPS-100-135 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |